SW1 to erase memory of the control unit :
- Power off the control Unit.
- Hold SW1 Swtich while restoring Power.
- Wait for the blue LED on the expansion bus to light up (approximately 10 seconds) while holding the switch down.
- Release SW1
SW2 to restore factory network settings (IP address : 192.168.2.150, mask 255.255.255.0).
- Power off the control Unit.
- Keep the switch pressed while turning the power back on.
Remark :
- To configure the control unit with a fixed IP address, release the switch at the first flash of the extension bus LED (about 5 seconds).
- To configure the control unit in DHCP mode, wait for the second flash of the extension bus LED (approximately 5 seconds after the first flash).
- Release SW2
Este artigo foi útil?
Isso é ótimo!
Obrigado pelo seu feedback
Lamentamos por não termos podido ajudá-lo(a)
Obrigado pelo seu feedback
Comentário enviado
Agradecemos o seu esforço e iremos tentar corrigir o artigo