How to Connect an Alarm Input Device to a Uniview NVR?

Endret Fri, 23 Aug ved 3:11 PM

How to Connect an Alarm Input Device to a

Uniview NVR?

Une image contenant logo, Police, Graphique, symbole

Description générée automatiquement

Step 1 Cable connection

The positive pole/Signal wire of the alarm input device is connected to the ALM IN port on the NVR. The negative pole/Ground wire of the alarm input device is connected to the G port on the NVR

 

Une image contenant diagramme, texte, capture d’écran, Police

Description générée automatiquement

 

 

Step 2 :

Set up input parameters of the alarm under Setup> Alarm>Alarm Input on the NVR’s web interface.

Une image contenant texte, logiciel, Icône d’ordinateur, Page web

Description générée automatiquement

 

Alarm Input No.: the alarm input port you are trying to configure. 

A<-1 refers to the NVR’s Alarm Input Port 1, 

A<-2 refers to the NVR’s Alarm Input Port 2, etc.

D1<-1 refers to the D1 camera’s Alarm Input Port 1, 

D3<-2 refers to the D3 camera’s Alarm Input Port 2,

Alarm Input Name: Set a name for it as you wish.

Alarm Type

- N.O. : Normally Open.

- N.C. : Normally Closed.

This needs to be set according to the attributes of the external alarm device.

Alarm Input: Switch to turn this alarm input on or off