How to Connect an Alarm Input Device to a Uniview NVR?

Modificato il Ven, 23 Ago alle 3:11 PM

This article is not available in Swedish, view it in French

How to Connect an Alarm Input Device to a

Uniview NVR?

Une image contenant logo, Police, Graphique, symbole

Description générée automatiquement

Step 1 Cable connection

The positive pole/Signal wire of the alarm input device is connected to the ALM IN port on the NVR. The negative pole/Ground wire of the alarm input device is connected to the G port on the NVR

 

Une image contenant diagramme, texte, capture d’écran, Police

Description générée automatiquement

 

 

Step 2 :

Set up input parameters of the alarm under Setup> Alarm>Alarm Input on the NVR’s web interface.

Une image contenant texte, logiciel, Icône d’ordinateur, Page web

Description générée automatiquement

 

Alarm Input No.: the alarm input port you are trying to configure. 

A<-1 refers to the NVR’s Alarm Input Port 1, 

A<-2 refers to the NVR’s Alarm Input Port 2, etc.

D1<-1 refers to the D1 camera’s Alarm Input Port 1, 

D3<-2 refers to the D3 camera’s Alarm Input Port 2,

Alarm Input Name: Set a name for it as you wish.

Alarm Type

- N.O. : Normally Open.

- N.C. : Normally Closed.

This needs to be set according to the attributes of the external alarm device.

Alarm Input: Switch to turn this alarm input on or off

Questo articolo ti è stato utile?

Fantastico!

Grazie per il tuo feedback

Siamo spiacenti di non poterti essere di aiuto

Grazie per il tuo feedback

Facci sapere come possiamo migliorare questo articolo!

Seleziona almeno uno dei motivi
La verifica CAPTCHA è richiesta.

Feedback inviato

Apprezziamo il tuo sforzo e cercheremo di correggere l’articolo